. . . ::: Electrical Equipment for Industrial Suppliers & Your Problem Electrical Solver (Jl. Kertajaya No. 185 F Surabaya 60282 - INDONESIA) ::: . . .
  • ACB (Air Circuit Breaker)
  • MCB Domae 3 Phasa 6 A sampai 20 A 4.5 kA
  • Altistart 01 Soft Start 15 kW 3 Phase ATS01N232QN
  • Inverter 1.5 kW 3 Phase 380 VAC ATV312HU15N4
  • Zelio Logic Paket Compact 24 VDC SR2PACKBD
  • Push Button Hijau XB5AA31
  • MCCB 3P 100A EasyPact EZC100N (EZC100N3100)
  • Kontaktor 3 Kutub (3 Phase) 9 A Koil 220 V AC LC1D09M7
  • CT 70 (100/5A dan 150/5A)
  • Ammeter 0-60 A, 0-75 A dan 0-100 A DIN96x96 mm
  • Rex Time Switch 037 53 Legrand
  • IP 44 - 16 A & 32 Plug dan Soket Industri 575 04
  • IP 44 - 16 A & 32 Plug dan Soket Industri 581 28
  • Katalog Kabel
  • GV2ME02 sampai GV2ME10
  • MCCB NSX100F - 36 kA 3P 11.2 - 50 A
  • Time Switch SUL 181 d
  • Eaton DX UPS
  • Surge Arrester PF40 3P+N 40 kA 15688
  • Power Monitoring Seri PM700 (PM700MG)
  • Timer AT8N Autonics
  • MCB C60N 6 kA 1 Phase 1 Ampere sampai 4 Ampere
  • Box Panel Metal IP 55 - IK 10 uk. 600 x 400 x 250 Legrand
  • Kapasitor Varplus Schneider

#17 of 18 | prev product Prev - Next next product
printer email

product arrow LY2 AC110/120 Omron

Price Rp 37,000
Rp 34,500
Beli
A Miniature Power Relay

• Equipped with arc barrier.
• Dielectric strength: 2,000 V.
• Built-in diode models added to the LY Series.
• Single-pole and double-pole models are applicable to operating coils with ratings of 100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC, or 100/110 VDC).
• Three-pole and four-pole models are applicable to operating coils with ratings of 100/110 VAC, 200/220 VAC, or 100/110 VDC).

■ Characteristics

* Contact resistance 50 mΩ max.
* Operate time 25 ms max.
* Release time 25 ms max.
* Max. operating frequency Mechanical: 18,000 operations/hr
* Max. operating frequency Electrical: 1,800 operations/hr (under rated load)
* Insulation resistance 100 MΩ min. (at 500 VDC)
* Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity, 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
* Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
* Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
* Shock resistance Destruction: 1,000 m/s2
* Shock resistance Malfunction: 200 m/s2
* Endurance Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)
* Endurance Mechanical: DC:  1,00,000,000 operations min. (at 18,000 operations/hr)
* Endurance Electrical: Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr under rated load), Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)
* Ambient temperature* Operating: Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing) (–25°C to 70°C if carry current is 4 A or less) All other Relays: –25°C to 40°C (with no icing) (–25°C to 55°C if carry current is 4 A or less)
* Ambient humidity Operating:  5% to 85%
* Weight Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g